Attachment J: Modifications to Altered
Facilities
1.
The City will
make the following modifications to the Campfield Branch Library
located at 30 Campfield Avenue, within 18 months of the effective date of this
Agreement:
A.
Parking
i.
Although the
parking lot has a total of 8 parking spaces, none are designated as van
accessible. On the shortest
accessible route to the accessible entrance, provide at least one van accessible
space a minimum of 96 inches wide, served by access aisles at least 96 inches
wide, with vertical signs with the International Symbol of Accessibility located
such that they cannot be obstructed by parked vehicles, and with an additional
AVan-Accessible@ sign located below the International Symbol
of Accessibility.
Standards '' 4.1.2(5)(b), 4.1.6(1)(b), 4.6,
4.30.7(1).
B.
Men=s and Women=s Single-User Toilet
Rooms
i.
The rear grab
bars at the toilets are inaccessible because they are 25 inches long. Provide a rear grab bar in each toilet
room that is at least 36 inches in overall length with the closer end no more
than 6 inches from the side wall.
Standards '' 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.17.6,
Fig. 30.
ii.
The toilet
paper dispensers are inaccessible because their tops are 2 inch under the side grab bars. Provide a toilet paper dispenser in each
toilet room that is mounted within reach, with its top at least 12 inches under the side grab bar, and centered
at least 19 inches above the finished floor. Standards ' 4.16.6, Fig.
29(b).
2.
Central
Library located at 500
Main Street - The City has submitted architectural drawings and specifications
for the City=s new addition
to the Central Library. By
September 30, 2005, the Department will review these materials for compliance
with the Standards and submit a report to the City outlining its findings. Upon receipt of the
Department=s report, the
City will incorporate the modifications needed to ensure that the design and
construction of the facilities comply with the Standards.
3.
The City will
make the following modifications to the Colt Park Pool and Bathhouse
located at Wethersfield Avenue, within 18 months of the effective date of this
Agreement:
A.
Parking
i.
The parking lot
is currently under construction. On the shortest accessible route to the
accessible entrance, provide the appropriate number of van accessible spaces and
standard spaces designated as reserved for people with disabilities. Standard accessible spaces shall be a
minimum of 96 inches wide and served by access aisles at least 60 inches
wide. Van accessible spaces shall
be a minimum of 96 inches wide and served by access aisles at least 96 inches
wide. All spaces designated as
reserved for people with disabilities shall have vertical signs with the
International Symbol of Accessibility located such that they cannot be
obstructed by parked vehicles. Van
accessible spaces shall have an additional AVan-Accessible@ sign located below the International Symbol
of Accessibility.
Standards '' 4.1.2(5), 4.1.6(1)(b), 4.6,
4.30.7(1).
B.
Accessible
Route
i.
The route from
the designated accessible parking to the main entrance gate is inaccessible
because it lacks a curb cut.
Provide a curb ramp that is at least 36 inches wide, has a maximum slope
of 1:12, is located so that it cannot be obstructed by parked vehicles, and has
a stable, firm, and slip-resistant surface with a detectable warning extending
the full width and depth of the ramp.
If the curb ramp is located where pedestrians must walk across it,
provide either flared sides (with a maximum slope of 1:10) or handrails or
guardrails to protect against cross traffic. Standards '' 4.1.2(1), 4.1.2(2), 4.1.6(1)(b), 4.3.8,
4.7, Fig. 12.
C.
Outside
Drinking Fountains
i.
Although there
are drinking fountains provided that are accessible to people who use
wheelchairs, there is no drinking fountain provided for people who have
difficulty bending or stooping.
Provide a drinking fountain that is accessible to people who have
difficulty bending or stooping.
This can be accommodated by the use of a Ahi-lo@ fountain; by providing one fountain
accessible to those who use wheelchairs and one fountain at a standard height
convenient for those who have difficulty bending; by providing a fountain
accessible to people who use wheelchairs and a cup dispenser, or by such other
means as would achieve the required accessibility for each group of people. Standards '' 4.1.3(10)(a),
4.1.6(1)(b).
4.
The City will
make the following modifications to the Cronin Park and Field House
located at Granby and Durham Streets, within 18 months of the effective date of
this Agreement:
A.
Men=s Toilet Room
i.
The toilet room
sign is mounted on the door.
Provide a toilet room sign with raised and Braille characters. The sign shall be mounted on the wall
adjacent to the latch side of the door with the centerline of the sign at 60
inches above the finished floor and situated such that a person can approach
within 3 inches of the sign without encountering an obstruction or standing
within a door swing.
Standards '' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6.
ii.
The paper towel
dispenser is inaccessible because the controls are mounted at 60 inches above
the finished floor. Provide a paper
towel dispenser with the controls a maximum height above the finished floor of
48 inches for a forward approach or 54 inches for a side approach and that is
accompanied by clear floor space of 30 by 48 inches that allows a forward or
parallel approach by a person using a wheelchair. Standards '' 4.1.3(13), 4.1.6(1)(b), 4.27.2, 4.27.3,
4.2.4, 4.2.5, 4.2.6.
iii.
The toilet
paper dispenser in the designated accessible stall is inaccessible because its
top is mounted directly underneath the side grab bar. Provide a toilet paper dispenser in each
toilet room that is mounted within reach, with its top at least 12 inches under the side grab bar, and centered
at least 19 inches above the finished floor. Standards ' 4.16.6, Fig.
29(b).
iv.
No accessible
coat hook has been provided.
Provide a coat hook at a maximum height above the finished floor of 48
inches for a forward approach or 54 inches for a side approach and that is
accompanied by clear floor space of 30 by 48 inches that allows a forward or
parallel approach by a person using a wheelchair. Standards '' 4.1.3(12)(a), 4.1.6(1)(b), 4.25.2,
4.25.3, 4.2.4, 4.2.5, 4.2.6.
B.
Women=s Toilet Room
i.
The toilet room
sign is mounted on the door.
Provide a toilet room sign with raised and Braille characters. The sign shall be mounted on the wall
adjacent to the latch side of the door with the centerline of the sign at 60
inches above the finished floor and situated such that a person can approach
within 3 inches of the sign without encountering an obstruction or standing
within a door swing.
Standards '' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6.
ii.
The paper towel
dispenser is inaccessible because the controls are mounted at 60 inches above
the finished floor. Provide a paper
towel dispenser with the controls a maximum height above the finished floor of
48 inches for a forward approach or 54 inches for a side approach and that is
accompanied by clear floor space of 30 by 48 inches that allows a forward or
parallel approach by a person using a wheelchair. Standards '' 4.1.3(13), 4.1.6(1)(b), 4.27.2, 4.27.3,
4.2.4, 4.2.5, 4.2.6.
iii.
No accessible
coat hook has been provided.
Provide a coat hook at a maximum height above the finished floor of 48
inches for a forward approach or 54 inches for a side approach and that is
accompanied by clear floor space of 30 by 48 inches that allows a forward or
parallel approach by a person using a wheelchair. Standards '' 4.1.3(12)(a), 4.1.6(1)(b), 4.25.2,
4.25.3, 4.2.4, 4.2.5, 4.2.6.
5.
The City will
make the following modifications to the Elizabeth Park Greenhouses and
Information Center located at Asylum Avenue, within 2 years of the effective
date of this Agreement:
A.
Parking
i.
The parking
reserved for persons with disabilities is inaccessible because the pavement
markings are unclear. Provide
designated accessible parking spaces and access aisles that have clear pavement
markings. 28 C.F.R. Part 35,
' 35.133.
ii.
The van
accessible parking reserved for persons with disabilities lacks the required
signage. At van accessible spaces,
provide a AVan-Accessible@ sign located below the International Symbol
of Accessibility such that the sign cannot be obstructed by vehicles parked in
the space.
Standards '' 4.1.2(5), 4.1.6(1)(b), 4.6.4,
4.30.7(1).
iii.
The parking
space reserved for persons with disabilities closest to the access road is
inaccessible because it does not have an access aisle and is not level. At this standard accessible space,
provide an access aisle at least 60 inches wide. Provide an access aisle that is flat and
level, with slopes and cross-slopes not exceeding 1:50 in all directions, and
that has surfaces that are firm, stable, and slip-resistant. Standards '' 4.1.2(5), 4.1.6(1)(b), 4.6.3, Fig.
9.
A.
Putnam
Greenhouse
i.
The entrance
door is inaccessible because there is a 2 inch change in level at the threshold
to the door. Provide an accessible
door with a threshold that is no greater than 3 inch, or is no greater than 2 inch and is beveled with a slope no greater
than 1:2. Standards '' 4.1.3(7)(a), 4.1.6(1)(b), 4.13.8,
4.5.2.
ii.
The entrance
door is inaccessible because it has knob hardware. Provide a door with hardware that is
easy to grasp with one hand and that does not require tight grasping, pinching,
or twisting of the wrist to operate.
Lever-operated mechanisms, push-type mechanisms, and U-shaped handles are
acceptable designs. Standards
' 4.13.9.
B.
Information
Center
i.
Unisex
Single-User Toilet Room
a.
No accessible
toilet room sign has been provided.
Provide a toilet room sign with the International Symbol of Accessibility
and raised and Braille characters.
The sign shall be mounted on the wall adjacent to the latch side of the
door with the centerline of the sign at 60 inches above the finished floor and
situated such that a person can approach within 3 inches of the sign without
encountering an obstruction or standing within a door swing. Standards '' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6, 4.30.7.
b.
The toilet is
inaccessible because the flush control is on the closed side. Provide a flush control mounted on the
Aopen@ side of the toilet=s clear floor space; 44 inches or less above
the finished floor; and requiring a maximum of 5 pounds of force to operate; or
provide an automatic flush device.
Standards '' 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.16.5,
4.27.4.
6.
The City will
make the following modifications to the Elizabeth Park Pond House and Pond
House Café located at Asylum Avenue, within 2 years of the effective date of
this Agreement:
A.
Parking
i.
Although the
parking lot has a parking space designated as reserved for people with
disabilities, it is not van accessible.
On the shortest accessible route to the accessible entrance, provide at
least one van accessible space a minimum of 96 inches wide, served by access
aisles at least 96 inches wide, with vertical signs with the International
Symbol of Accessibility located such that they cannot be obstructed by parked
vehicles, and with an additional AVan-Accessible@ sign located below the International Symbol
of Accessibility. Standards
'' 4.1.2(5)(b), 4.1.6(1)(b), 4.6,
4.30.7(1).
B.
Pond House Toilet Facility
i.
There is no
signage at this inaccessible toilet room facility directing people with
disabilities to the accessible toilet rooms located in the Information Center
and in the Pond House Café. Provide
accessible directional signage with the International Symbol of Accessibility at
inaccessible toilet rooms indicating the location of the nearest accessible
toilet rooms, and provide accessible signage with the International Symbol of
Accessibility at all accessible toilet rooms. Standards '' 4.1.2(7)(d), 4.1.6(3)(e)(iii), 4.30.1,
4.30.2, 4.30.3, 4.30.5, 4.30.7.
C.
Drinking Fountain located in the Pond House Café
i.
Although a
drinking fountain accessible to people who use wheelchairs is provided, there is
no drinking fountain provided for people who have difficulty bending or
stooping. Provide a drinking
fountain that is accessible to people who have difficulty bending or
stooping. This can be accommodated
by the use of a Ahi-lo@ fountain; by providing one fountain
accessible to those who use wheelchairs and one fountain at a standard height
convenient for those who have difficulty bending; by providing a fountain
accessible to people who use wheelchairs and a cup dispenser, or by such other
means as would achieve the required accessibility for each group of people. Standards '' 4.1.3(10)(a),
4.1.6(1)(b).
D.
Men=s Toilet Room located in the Pond House Café
i.
The urinal
is inaccessible because the width between the partitions is 28 inches. Provide a urinal with a clear floor
space of at least 30 inches wide and 48 inches deep centered on the urinal. Standards '' 4.1.3(11), 4.1.6(1)(b), 4.22.5, 4.18.2,
4.18.3, 4.18.4.
7.
The City will
make the following modifications to the Fire Training Academy located at
1 Fischer Road, within 14 months of the effective date of this Agreement:
A.
Parking
i.
Although the
parking lot has a total of 45 parking spaces, none are van accessible. On the shortest accessible route to the
accessible entrance, provide at least one van accessible space a minimum of 96
inches wide, served by access aisles at least 96 inches wide, with vertical
signs with the International Symbol of Accessibility located such that they
cannot be obstructed by parked vehicles, and with an additional AVan-Accessible@ sign located below the International Symbol
of Accessibility.
Standards '' 4.1.2(5)(b), 4.1.6(1)(b), 4.6,
4.30.7(1).
ii.
The parking
spaces designated as reserved for people with disabilities are inaccessible
because there are no access aisles.
At each standard accessible space, provide an access aisle at least 60
inches wide. At each van accessible
space, provide an access aisles at least 96 inches wide. Provide access aisles that are flat and
level, with slopes and cross-slopes not exceeding 1:50 in all directions, and
that their surfaces are firm, stable, and slip-resistant. Standards '' 4.1.2(5), 4.1.6(1)(b), 4.6.3, Fig.
9.
B.
Inaccessible Men=s and Women=s Toilet
Rooms
i.
There is no
signage directing people with disabilities to the accessible toilet rooms. Provide accessible directional signage
with the International Symbol of Accessibility at inaccessible toilet rooms
indicating the location of the nearest accessible toilet room, and provide
accessible signage with the International Symbol of Accessibility at all
accessible toilet rooms. Standards
'' 4.1.2(7)(d), 4.1.6(3)(e)(iii), 4.30.1,
4.30.2, 4.30.3, 4.30.5, 4.30.7.
C.
Unisex
Single-User Toilet and Shower Room located on the First
Floor
i.
No accessible
toilet/shower room sign has been provided.
Provide a toilet/shower room sign with the International Symbol of
Accessibility and raised and Braille characters. The sign shall be mounted on the wall
adjacent to the latch side of the door with the centerline of the sign at 60
inches above the finished floor and situated such that a person can approach
within 3 inches of the sign without encountering an obstruction or standing
within a door swing. Standards
'' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6, 4.30.7.
ii.
The door is
inaccessible because the pressure required to open the door is 11 pounds. Provide a door that requires no more
than 5 pounds of force to open.
Standards '' 4.1.3(7)(b), 4.1.6(1)(b),
4.13.11(2)(b).
iii.
The toilet is
inaccessible because the flush control is on the closed side. Provide a flush control mounted on the
Aopen@ side of the toilet=s clear floor space; 44 inches or less above
the finished floor; and requiring a maximum of 5 pounds of force to operate; or
provide an automatic flush device.
Standards '' 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.16.5,
4.27.4.
iv.
The rear grab
bar at the toilet is inaccessible because it is 25 inches long. Provide a rear grab bar that is at least
36 inches in overall length with the closer end no more than 6 inches from the
side wall.
Standards '' 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.16.4,
Fig. 29.
8.
Goodwin Branch
Library located at 460
New Britain Avenue - The City has submitted architectural drawings and
specifications for the renovation plans of Goodwin Branch Library. By September 30, 2005, the Department
will review these materials for compliance with the Standards and submit a
report to the City outlining its findings.
Upon receipt of the Department=s report, the
City will incorporate the modifications needed to ensure that the design and
construction of the facilities comply with the Standards.
9.
The City will
make the following modifications to the Goodwin Park, Bucior Pool, and
Bathhouse located at Hubbard Road and South Street, within 14 months of the
effective date of this Agreement:
A.
Women=s Singe-User Toilet
Room
i.
The toilet room
sign does not have the International Symbol of Accessibility. Provide a toilet room sign with the
International Symbol of Accessibility.
Standards '' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6, 4.30.7.
A.
Men=s Single-User Toilet
Room
i.
The toilet room
sign does not have the International Symbol of Accessibility. Provide a toilet room sign with the
International Symbol of Accessibility.
Standards '' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6, 4.30.7.
10.
The City will
make the following modifications to the Keney Park - Barbour Field House
located at Barbour and Tower Avenues, within 14 months of the effective date of
this Agreement:
A.
Parking
i.
The parking lot
provides no parking reserved for people with disabilities. On the shortest accessible route to the
accessible entrance, provide the appropriate number of van accessible spaces and
standard spaces designated as reserved for people with disabilities. Provide standard accessible spaces that
are a minimum of 96 inches wide and served by access aisles at least 60 inches
wide. Provide van accessible spaces
that are a minimum of 96 inches wide and served by access aisles at least 96
inches wide. At all spaces
designated as reserved for persons with disabilities, provide vertical signs
with the International Symbol of Accessibility located such that they cannot be
obstructed by parked vehicles. At
van accessible spaces, provide an additional AVan-Accessible@ sign located below the International Symbol
of Accessibility. Provide spaces
and access aisles for persons with disabilities that are flat and level, with
slopes and cross-slopes not exceeding 1:50 in all directions, and that their
surfaces are firm, stable, and slip-resistant. Standards '' 4.1.2(5), 4.1.6(1)(b), 4.6,
4.30.7(1).
A.
Drinking
Fountain located in the Field House
i.
The
wall-mounted drinking fountain is inaccessible because there is insufficient
clear floor space to access the fountain.
Provide a drinking fountain with clear knee space between the bottom of
the apron and the finished floor or ground of at least 27 inches high, 30 inches
wide, and 17 to 19 inches deep; and a minimum clear floor space of 30 inches by
48 inches to allow a person in a wheelchair to approach the unit facing
forward. Standards '' 4.1.3(10), 4.1.6(1)(b), 4.15.5(1),
Figs. 27(a), (b).
ii.
Although a
drinking fountain accessible to persons who use wheelchairs is provided, there
is no drinking fountain provided for people who have difficulty bending or
stooping. Provide a drinking
fountain that is accessible to people who have difficulty bending or
stooping. This can be accommodated
by the use of a Ahi-lo@ fountain; by providing one fountain
accessible to those who use wheelchairs and one fountain at a standard height
convenient for those who have difficulty bending; by providing a fountain
accessible to people who use wheelchairs and a cup dispenser, or by such other
means as would achieve the required accessibility for each group of people. Standards '' 4.1.3(10)(a),
4.1.6(1)(b).
B.
Men=s Toilet Room
i.
The toilet room
sign does not have raised and Braille characters. Provide a toilet room sign with raised
and Braille characters. Standards '' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6.
ii.
The path of
travel into the toilet room is inaccessible because the wall-mounted air dryer
is not detectable to a blind person using a cane. Provide an accessible route into the
toilet room such that no objects with their bottom leading edges measuring
between 27 inches and 80 inches above the finished floor protrude more than 4
inches into walks, halls, corridors, passageways, or aisles. Free-standing objects mounted on posts
or pylons may overhang 12 inches maximum from 27 inches to 80 inches above the
ground or finished floor. Standards
'' 4.1.2(3), 4.4.
iii.
The toilet
paper dispenser in the designated accessible stall is inaccessible because it is
39 inches from the rear wall.
Provide a toilet paper dispenser that is mounted with its top at least
12 inches under the side grab bar and 36 inches
or less from the rear wall and is centered at least 19 inches above the finished
floor. Standards '' 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.17.3,
Fig. 30(d).
C.
Women=s Toilet Room
i.
The toilet room
sign does not have raised and Braille characters. Provide a toilet room sign with raised
and Braille characters.
Standards '' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6.
ii.
The path of
travel into the toilet room is inaccessible because the wall-mounted air dryer
is not detectable to a blind person using a cane. Provide an accessible route into the
toilet room such that no objects with their bottom leading edges measuring
between 27 inches and 80 inches above the finished floor protrude more than 4
inches into walks, halls, corridors, passageways, or aisles. Free-standing objects mounted on posts
or pylons may overhang 12 inches maximum from 27 inches to 80 inches above the
ground or finished floor. Standards
'' 4.1.2(3), 4.4.
iii.
The toilet
paper dispenser in the designated accessible stall is inaccessible because it is
39 inches from the rear wall.
Provide a toilet paper dispenser that is mounted with its top at least
12 inches under the side grab bar and 36 inches
or less from the rear wall and is centered at least 19 inches above the finished
floor. Standards '' 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.17.3,
Fig. 30(d).
11.
The City will
make the following modifications to the Keney Park - Waverly Field House
located at Vine and Edgewood Streets, within 14 months of the effective date of
this Agreement:
A.
Parking
i.
The signage
designating parking as reserved for persons with disabilities is too low. At each space designated as reserved for
persons with disabilities, provide a vertical sign with the International Symbol
of Accessibility located such that it cannot be obstructed by vehicles parked in
the space. Standards '' 4.1.2(5), 4.1.6(1)(b), 4.6.4,
4.30.7(1).
ii.
The van
accessible parking reserved for persons with disabilities lacks the appropriate
signage. At van accessible spaces,
provide a AVan-Accessible@ sign located below the International Symbol
of Accessibility such that the sign cannot be obstructed by vehicles parked in
the space. Standards '' 4.1.2(5), 4.1.6(1)(b), 4.6.4,
4.30.7(1).
A.
Picnic
Tables
i.
The picnic
tables are inaccessible. Provide at
least one picnic table on an accessible route such that there is knee space at
the table at least 27 inches high, 30 inches wide, and 19 inches deep, and such
that the height of the top of the table is between 28 inches and 34 inches above
the ground. Standards '' 4.1.3(18), 4.1.6(1)(b), 4.32.3,
4.32.4.
B.
Men=s Toilet Room
i.
The toilet room
sign is inaccessible because it is mounted on the door. Provide a toilet room sign that is
mounted on the wall adjacent to the latch side of the door with the centerline
of the sign at 60 inches above the finished floor and situated such that a
person can approach within 3 inches of the sign without encountering an
obstruction or standing within a door swing. Standards '' 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1,
4.30.4, 4.30.5, 4.30.6.
ii.
No accessible
coat hook has been provided.
Provide a coat hook at a maximum height above the finished floor of 48
inches for a forward approach or 54 inches for a side approach and that is
accompanied by clear floor space of 30 by 48 inches that allows a forward or
parallel approach by a person using a wheelchair. Standards '' 4.1.3(12)(a), 4.1.6(1)(b), 4.25.2,
4.25.3, 4.2.4, 4.2.5, 4.2.6.
iii.
The toilet
paper dispenser in the designated accessible stall is inaccessible because it is
45 inches from the rear wall.
Provide a toilet paper dispenser that is mounted with its top at least
12 inches under the side grab bar and 36 inches
or less from the rear wall and is centered at least 19 inches above the finished
floor. Standards '' 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.17.3,
Fig. 30(d).
C. Women=